Controllogix instruction set manual




















Otherwise, for existing networks the following are helpful. The links are from the AB site so they are the latest and greatest manuals. Let me know if any of them are broken or if I forgot one you think is essential. Jus for my own knowledge and learning process I have decided to post this out there.

I have little experience with PLC's but enough to be dangerous. Also Device Net and its ease of use. What is ControlNet? Thanks and appreciate your help.

PLC is more for automation and machine control. I am not sure if this would be a good choice for what you are looking for. Thanks for the effort of preparing this website and collating all the relevant link! Exactly what I am looking for being relatively new to PLC programming.

Many thanks for your kind generosity in sharing out this wealth of information, much appreciated. This website very nice, all the article easy download and very useful Thanks for all of you, who keep this site always exist.

Hi, I am working on a system where i want to be able to load default values into alarm levels before each run of the process. Is there a way to have the values in an array and have the locations they need to go in another array and have the AB ladder logic step through the arrays to set the values, instead of having a rung for each alarm level.

Any help would be greatly appreciated. Tools for PLC programming. Navigation Book reviews Online books Recent posts About. Before you begin using your ControlLogix controller, verify that you have the applications that are required to configure and program the controller. Use Table 3 to identify the minimum software versions that are required to use your ControlLogix controller.

These documents contain additional information concerning related products from Rockwell Automation. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Install the L7 x Controller. ATTENTION: Personnel responsible for the application of safety-related programmable electronic systems PES shall be aware of the safety requirements in the application of the system and shall be trained in using the system.

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications as defined in IEC , at altitudes up to m ft without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments. This equipment is supplied as open-type equipment.

It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be approved for the application if nonmetallic.

The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. Each product is supplied. When combining products within a system, the most adverse temperature code.

Lorsque plusieurs produits. Combinations of equipment in your system are subject to investigation by the. The enclosure must utilize a tool removable cover or door. See IN to install a ControlLogix chassis and power supply before you install your controller and power supply. These sections describe parts that are included with the L7 x controllers and available accessory parts.

Figure 1 - Parts with the L7 x Controller. We recommend that you leave the SD card installed. You can choose to use the parts included with the controller and these parts specific to your application. The USB cable is not to exceed 3. These sections explain how to install the L7 x controller.

To install the L7 x controller, complete the tasks summarized in this table. You can install or remove a ControlLogix controller while chassis power is on and the system is operating. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding.

Repeated electrical arcing causes excessive wear to contacts on both the controller and its mating connector on the chassis. Worn contacts may create electrical resistance that can affect controller operation. This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment:. Slide the module into the chassis until it snaps into place.

Verify that the controller is flush with the power supply or other installed modules. After you have inserted the controller into the chassis, reference the Troubleshoot the Module on page for information to interpret the status indicators. Complete these steps to install the SD card in the L7 x controllers. It is recommended that you leave the SD card in the controller, even when it is not used.

If the controller experiences a Major nonrecoverable Fault, extended fault information is saved to the card. The L7 x controller ships with an SD card installed. Complete these steps to remove the SD card from the L7 x controller. If you use an SD card other than those cards that are available from Rockwell Automation, you can experience data corruption or loss.

To install an ESM in the L7 x controller, complete these steps. Slide the ESM back until it snaps into place. The ESM begins charging after installation. The following status messages indicate charging status:.

After you install the ESM, it can take up to 15 seconds for the charging status messages to display. To verify that the ESM is fully charged, check the status display to confirm that. In this case, complete these steps before you remove the ESM.

There is no visual indication of when the 20 minutes has expired. You must track that time period. Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. After the OK status indicator transitions to Off, go to step 2.

Use your thumb to press down on the black release and pull the ESM away from the controller. Install the L6 x Controller. These sections describe parts that are included with the L6 x controllers and available accessory parts:.

Figure 2 - Parts Included with the L6 x Controller. Series B controllers use battery power differently than previous controllers and therefore battery considerations for this series controller vary. For more information to determine what battery to use, see the ControlLogix Controllers Selection Guide,. These sections explain how to install a L6 x controller. To install the L6 x controller, complete the tasks summarized in this table.

Lay the controller on its side with the front facing to the left. Insert the CompactFlash card into the slot at the bottom of the controller. Pull the clip forward and downward until it snaps into place over the card. Lay the controller in its side with the mode switch facing left. Gently pull the card out of the slot. Open the door of the controller and push the CompactFlash latch to the left. Release the latch and secure it over the CompactFlash card. Verify that the OK indicator is solid green and open the door of the controller.

Push and hold the CompactFlash latch to the left. Push the eject button and remove the card. This product contains a hermetically-sealed lithium battery that may need to be replaced during the life of the product. At the end of its life, the battery contained in this product should be collected separately from any unsorted municipal waste. The collection and recycling of batteries helps protect the environment and contributes to the conservation of natural resources as valuable materials are recovered.

For safety information on the handling of lithium batteries, including handling and disposal of leaking batteries, see Guidelines for Handling Lithium Batteries, publication AG We recommend. The use of other batteries can damage the controller. Connect the battery connector to the port to the right of the battery slot. Snap the battery into the battery slot.

Write the date on the battery label. Attach the label to the inside of the controller door. Insert the battery, with the arrow pointing up, into the battery slot. You can install a ControlLogix controller while chassis power is on and the system is operating. Insert the key into the controller. Turn the key to the PROG position. Align the circuit board with the top and bottom guides in the chassis.

Slide the module into the chassis. Verify that the top and bottom latches are engaged. After you have inserted the controller into the chassis, you can reference the Troubleshoot the Module on page for more information that is related to the state of the controller.

You can remove a controller while chassis power is on and the system is operating. The devices that are owned by the controller go to their configured fault state if you remove the controller. Repeated electrical arcing causes excessive wear to contacts on both the controller and its mating connector in the chassis. Press the locking tabs on the top and bottom of the controller.

Slide the controller out of the chassis. Before you can begin using your controller, you must make a connection to the controller. Connection options with the L7 x include the following:. Connection options with the L6 x include the following:. When upgrading your L6 x controller firmware, we recommend you use a. The port is USB 2. With this connection, you can upgrade firmware and download programs to the controller directly from your workstation.

Connect your controller and workstation by using a USB cable. The Found New Hardware Wizard dialog box appears. Click Install the software automatically Recommended and click Next. The software is installed. Click Finish to configure your USB driver. Your controller appears under two drivers, a virtual chassis and the USB port. You can use either driver to browse to your controller. The L6 x ControlLogix controller uses a serial port for workstation connections.

WARNING: If you connect or disconnect the serial cable with power applied to this module or the serial device on the other end of the cable, an electrical arc can occur. To connect a workstation to the serial port, you can make your own serial cable or use one of these cables:. To Controller. Plug the controller end of the serial cable into the RS port on the front of the controller. Welcome to ManualMachine. We have sent a verification link to to complete your registration.

Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password.

Rockwell Automation. New and Updated Information. This table contains the changes made to this revision. Throughout publication. Table of Contents Preface Studio Environment.

Serial Communication on L6x Controllers. This environment is the one place for design engineers to develop the elements of their control system.

Preface For detailed information about GuardLogix safety controllers, see the following publications.

Resource Description GuardLogix Controllers User Manual, publication Provides information on how to install, configure, and UM operate GuardLogix controllers in Studio , version 21 or later projects. GuardLogix Controller System Safety Reference Provides information on how to meet safety application Manual, publication RM requirements for GuardLogix controllers in Studio , version 21 or later projects.

Required Software Use Table 3 to identify the minimum software versions that are required to use your ControlLogix controller. Logix Controllers Nonvolatile Memory Card Provides information about changing the project that is Programming Manual, publication PM available to load from nonvolatile memory, Logix Controllers Produced and Consumed Tags Provides more information for produced and consumed Programming Manual, publication PM tags.

Chapter 1 Install the L7x Controller. Parts Available for Use with the L7 x Controller You can choose to use the parts included with the controller and these parts specific to your application. Install the L7x Controller Chapter 1. Chapter 1 Install the L7x Controller 1. Top Circuit Board Aligned. Insert the Key After the controller is installed, insert the key. Verify that the SD card is locked or unlocked according to your preference.

Open the door for the SD card. Logix 55xx OK 3. Insert the SD card into the SD card slot. Chapter 1 Install the L7x Controller 4. Gently press the card until it clicks into place.

Close the SD card door. Open the door to access the SD card. Press and release the SD card to eject it. Remove the SD card and close the door. Align the tongue-and-groove slots of the ESM and controller.

Failure to do so can result in the loss of the application program. A type 1, code 40 major fault is logged on powerup. The ESM contains a real-time clock.

If the ESM is new or came from another controller, the WallClockTime object attributes for your controller can change. Complete these steps to remove an ESM module from the controller. Remove the key from the mode switch. Install the L7x Controller Chapter 1 2. Chapter 1 Install the L7x Controller Notes:. Chapter 2 Install the L6x Controller. The installation and removal of a CompactFlash card depends on the controller.

Raise the locking clip. Release the latch. Install the L6x Controller Chapter 2. If the temperature 2. Complete these steps to insert the controller into the chassis. Install the L6x Controller Chapter 2 5. Complete these steps to remove the controller from the chassis. Chapter 3 Start Using the Controller. Connect to the L7 x Controller. TIP When upgrading your L6 x controller firmware, we recommend you use a network connection other than the serial cable.

Serial connections are much slower than other communication connections. To configure a USB driver, perform this procedure.

Click any of the Windows Update connection options and click Next. The RSLinx Workstation organizer appears. Start Using the Controller Chapter 3. Connect to the L6 x Controller. To configure the driver, perform this procedure. You can only view or download manuals with.

Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for. Register and get 5 for free. Upload manuals that we do not have and get 1 for each file.

Get 1 for every download of your manual. Buy as much as you need. Extreme Environment ControlLogix Controllers. Parts Available for Use with the L7x Controller. Parts Not Included with the L6x Controller.

Use the Controller Status Menu to Download. System, Communication, and Programming Features. Online Additions - ControlNet Considerations. Configure the System Overhead Time Slice. How Equipment Changes States. ControlLogix Redundancy Overview.



0コメント